RS-449/RS-422


 

DTE

DCE

Стандарт RS449 отображает спецификацию конструктива и не является электрическим интерфейсом. Этот разъём был разработан для поддержки балансных сигналов RS422 интерфеса, и небалансных сигналов RS423 интерфейса. Оба этих интерфейса наследуют свойства RS232.

Pin

Name

V.24

Dir

Description

Type

1

 

101

Shield

Ground

2

SI

112

Signal Rate Indicator

Control

3

n/a

 

n/a

unused

 

4

SD-

103

Send Data (A)

Data

5

ST-

114

Send Timing (A)

Timing

6

RD-

104

Receive Data (A)

Data

7

RS-

105

Request To Send (A)

Control

8

RT-

115

Receive Timing (A)

Timing

9

CS-

106

Clear To Send (A)

Control

10

LL

141

Local Loopback

Control

11

DM-

107

Data Mode (A)

Control

12

TR-

108.2

Terminal Ready (A)

Control

13

RR-

109

Receiver Ready (A)

Control

14

RL

140

Remote Loopback

Control

15

IC

125

Incoming Call

Control

16

SF/SR+

126

Signal Freq./Sig. Rate Select.

Control

17

TT-

113

Terminal Timing (A)

Timing

18

TM-

142

Test Mode (A)

Control

19

SG

102

Signal Ground

Ground

20

RC

102b

Receive Common

Ground

21

n/a

 

n/a

unused

 

22

SD+

103

Send Data (B)

Data

23

ST+

114

Send Timing (B)

Timing

24

RD+

104

Receive Data (B)

Data

25

RS+

105

Request To Send (B)

Control

26

RT+

115

Receive Timing (B)

Timing

27

CS+

106

Clear To Send (B)

Control

28

IS

n/a

Terminal In Service

Control

29

DM+

107

Data Mode (B)

Control

30

TR+

108.2

Terminal Ready (B)

Control

31

RR+

109

Receiver Ready (B)

Control

32

SS

116

Select Standby

Control

33

SQ

110

Signal Quality

Control

34

NS

n/a

New Signal

Control

35

TT+

113

Terminal Timing (B)

Timing

36

SB

117

Standby Indicator

Control

37

SC

102a

Send Common

Ground

 

RS449 высокоскоростной цифровой интерфейс, но  в отличие от RS232 базирующегося на определении электрических сигналов относительно земли, RS449 V.11 при приёме данных ориентируется на разнице сигналов между парой проводов. При передаче данных по двум проводам, соединённым по технологии “витая пара” любые помехи, возникающие на одном из проводов возникают и на другом. В интерфейсе RS449 шумы передаются одновременно по двум проводам, одинаково относительно земли. Но эти помехи не влияю на разницу напряжения информационных сигналов. Приёмники же определяют только разницу напряжения между этими двумя проводами, не включая сигнал ground.

Различные сигналы для RS449 интерфейса помечаются каждый как «A» и «B» или «+» и «-«. Контакты, помеченные как «A» или «+» нельзя подключать  к контатам «B» или  «-«. Контакт A всегда должен быть соединён с «A» и контакт «B» должен быть соединён с «B» или “+” с “+” и “-“ с “-“.

При изготолвении кросс-кабелей, в первую очередь, необходимо проверить соблюдение полярности сигналов.

Существуют следующие варианты наименования: EIA-449, RS-449, ISO 4902.

Primary channel

Note: Direction is DTE (Computer) relative DCE (Modem).

Name

Description

Function

AA

Shield Ground

Also known as protective ground. This is the chassis ground connection between DTE and DCE.

AB

Signal Ground

The reference ground between a DTE and a DCE. Has the value 0 Vdc.

BA

Transmitted Data

Data send by the DTE.

BB

Received Data

Data received by the DTE.

CA

Request To Send

Originated by the DTE to initiate transmission by the DCE.

CB

Clear To Send

Send by the DCE as a reply on the RTS after a delay in ms, which gives the DCEs enough time to energize their circuits and synchronize on basic modulation patterns.

CC

DCE Ready

Known as DSR. Originated by the DCE indicating that it is basically operating (power on, and in functional mode).

CD

DTE Ready

Known as DTR. Originated by the DTE to instruct the DCE to setup a connection. Actually it means that the DTE is up and running and ready to communicate.

CE

Ring Indicator

A signal from the DCE to the DTE that there is an incomming call (telephone is ringing). Only used on switched circuit connections.

CF

Received Line Signal Detector

Known as DCD. A signal send from DCE to its DTE to indicate that it has received a basic carrier signal from a (remote) DCE.

CH/CI

Data Signal Rate Select
(DTE/DCE Source>

A control signal that can be used to change the transmission speed.

DA

Transmit Signal Element Timing
(DTE Source)

Timing signals used by the DTE for transmission, where the clock is originated by the DTE and the DCE is the slave.

DB

Transmitter Signal Element Timing
(DCE Source)

Timing signals used by the DTE for transmission.

DD

Receiver Signal Element Timing
(DCE Source)

Timing signals used by the DTE when receiving data.

IS

terminal In Service

Signal that indicates that the DTE is available for operation

NS

New Signal

A control signal from the DTE to the DCE. It instructs the DCE to rapidly get ready to receive a new analog signal. It helps master-station modems rapidly synchronize on a new modem at a tributary station in multipoint circuits

RC

Receive Common

A signal return for receiver circuit reference

LL

Local Loopback / Quality Detector

A control signal from the DTE to the DCE that causes the analog transmision output to be connected to the analog receiver input.

RL

Remote Loopback

Signal from the DTE to the DCE. The local DCE then signals the remote DCE to loopback the analog signal and thus causing a line loopback.

SB

Standby Indicator

Signal from the DCE to indicate if it is uses the normal communication or standby channel

SC

Send Common

A return signal for transmitter circuit reference

SF

Select Frequency

A signal from the DTE to tell the DCE which of the two analog carrier frequencies should be used.

SS

Select Standby

A signal from DTE to DCE, to switch between normal communication or standby channel.

TM

Test Mode

A signal from the DCE to the DTE that it is in test-mode and can"t send any data.

 

Reserved for Testing

 

Спецификация  EIA RS449 описывает основные функциональные и физические особенности интерфейса RS449 соединяющего оборудование DTE и DCE известна как  EIA электрический интерфейс стандартов RS422 и RS423.

 

Последнее с форума
Ответов: [0]
04.12.18 06:20 / lsdussr
Последний ответ:
04.12.18 06:20 / lsdussr
Ответов: [1]
11.02.17 12:09 / butuz
Последний ответ:
11.02.17 13:09 / Alexander
Ответов: [2]
07.07.17 06:39 / butuz
Последний ответ:
07.07.17 10:17 / butuz
Ответов: [11]
06.06.17 06:14 / CrimeaMan
Последний ответ:
06.23.17 14:18 / Krutikov
Ответов: [0]
05.30.17 15:33 / umka911
Последний ответ:
05.30.17 15:33 / umka911
Ответов: [4]
04.24.17 16:39 / umka911
Последний ответ:
04.26.17 10:08 / umka911
Нужна дополнительная информация? Задайте вопрос специалисту!
Имя:*
E-mail:*
Телефон:
Вопрос:*

Обновить картинку

Введите код с картинки (4 цифры):*